This is Dataplot data file HEALY1.DAT Optimization of Hot Plate Gap Parameters via ANSYS (Computer Experiment) Bill Healy (NIST) 2**(6-2) fractional factorial Design + center point Response variable = apparent thermal conductivity Number of observations = 17 (= 16 + 1) Number of variables per line image = 8 Order of variables on a line image-- 1. Response variable 1 = Relative error in conductivity 2. Response variable 2 = Gap temperature difference 3. Factor 1 = Gap size (2 levels: .001 and .002) 4. Factor 2 = Gap insulation material (2 levels: .001 and .200) 5. Factor 3 = Insulation thickness (2 levels: .01 and .11) 6. Factor 4 = Insulation conductivity (2 levels: .002 and .500) 7. Factor 5 = Plate conductivity (2 levels: 100 and 400) 8. Factor 6 = Surface temperature (2 levels: 5 and 45) To read this file into Dataplot-- SKIP 25 READ HEALY1.DAT Y1 Y2 X1 X2 X3 X4 X5 X6 Y1 Y2 X1 X2 X3 X4 X5 X6 ------------------------------------------------------------ -0.008 4.00E-05 -1 -1 -1 -1 -1 -1 -0.05597 0.00038 +1 -1 -1 -1 +1 -1 0.002222 0 -1 +1 -1 -1 +1 +1 0.002222 0 +1 +1 -1 -1 -1 +1 0 0 -1 -1 +1 -1 +1 +1 -0.00444 2.22E-05 +1 -1 +1 -1 -1 +1 0 0 -1 +1 +1 -1 -1 -1 0 0 +1 +1 +1 -1 +1 -1 -0.02666 0.000422 -1 -1 -1 +1 -1 +1 -0.11321 0.000867 +1 -1 -1 +1 +1 +1 -0.006 8.00E-05 -1 +1 -1 +1 +1 -1 -0.05797 0.0005 +1 +1 -1 +1 -1 -1 -0.002 2.00E-05 -1 -1 +1 +1 +1 -1 -0.012 0.00014 +1 -1 +1 +1 -1 -1 0.002222 0 -1 +1 +1 +1 -1 +1 -0.00444 4.44E-05 +1 +1 +1 +1 +1 +1 -0.004 4.00E-05 0 0 0 0 0 0