2.
Measurement Process Characterization
2.3. Calibration 2.3.4. Catalog of calibration designs 2.3.4.1. Mass weights
|
|||
Design 1,1,1
OBSERVATIONS 1 1 1 Y(1) + - Y(2) + - Y(3) + - RESTRAINT + CHECK STANDARD + DEGREES OF FREEDOM = 1 SOLUTION MATRIX DIVISOR = 3 OBSERVATIONS 1 1 1 Y(1) 0 -2 -1 Y(2) 0 -1 -2 Y(3) 0 1 -1 R* 3 3 3 R* = value of reference weight FACTORS FOR REPEATABILITY STANDARD DEVIATIONS WT FACTOR 1 1 1 1 0.0000 + 1 0.8165 + 1 0.8165 + 2 1.4142 + + 1 0.8165 + FACTORS FOR BETWEEN-DAY STANDARD DEVIATIONS WT FACTOR 1 1 1 1 0.0000 + 1 1.4142 + 1 1.4142 + 2 2.4495 + + 1 1.4142 + |