Next Page Previous Page Home Tools & Aids Search Handbook
2. Measurement Process Characterization
2.3. Calibration
2.3.4. Catalog of calibration designs
2.3.4.3. Designs for electrical quantities

2.3.4.3.3.

Left-right balanced design for 5 standard cells

Design 1,1,1,1,1

OBSERVATIONS     1   1   1   1   1


      Y(1)       +   -
      Y(2)       +       -
      Y(3)           +   -
      Y(4)           +       -
      Y(5)               +   -
      Y(6)               +       -
      Y(7)                   +   -
      Y(8)       -           +
      Y(9)       -               +
      Y(10)          -           +


  RESTRAINT      +   +   +   +   +


  DEGREES OF FREEDOM  =  5


                            SOLUTION MATRIX
                              DIVISOR = 5

  OBSERVATIONS      1      1      1      1      1      P


     Y(1)           1     -1      0      0      0      1
     Y(2)           1      0     -1      0      0      1
     Y(3)           0      1     -1      0      0      1
     Y(4)           0      1      0     -1      0      1
     Y(5)           0      0      1     -1      0      1
     Y(6)           0      0      1      0     -1      1
     Y(7)           0      0      0      1     -1      1
     Y(8)          -1      0      0      1      0      1
     Y(9)          -1      0      0      0      1      1
     Y(10)          0     -1      0      0      1      1
     R*             1      1      1      1      1      0

     R* = AVERAGE VALUE OF 5 REFERENCE CELLS

     P = LEFT-RIGHT BIAS


  FACTORS FOR COMPUTING REPEATABILITY STANDARD DEVIATIONS
   V  FACTOR          CELLS
                1   1   1   1   1
   1  0.4000    +
   1  0.4000        +
   1  0.4000            +
   1  0.4000                +
   1  0.4000                    +
Explanation of notation and interpretation of tables
Home Tools & Aids Search Handbook Previous Page Next Page