2.
Measurement Process Characterization
2.3. Calibration 2.3.4. Catalog of calibration designs 2.3.4.3. Designs for electrical quantities
|
|||
Design 1,1,1,1,1,1
CELLS
OBSERVATIONS 1 1 1 1 1 1
Y(1) + -
Y(2) + -
Y(3) + -
Y(4) + -
Y(5) + -
Y(6) + -
Y(7) + -
Y(8) + -
Y(9) + -
Y(10) - +
Y(11) - +
Y(12) - +
Y(13) + -
Y(14) + -
Y(15) + -
RESTRAINT + + + + + +
DEGREES OF FREEDOM = 9
SOLUTION MATRIX
DIVISOR = 6
OBSERVATIONS 1 1 1 1 1 1 P
Y(1) 1 -1 0 0 0 0 1
Y(2) 1 0 -1 0 0 0 1
Y(3) 0 1 -1 0 0 0 1
Y(4) 0 1 0 -1 0 0 1
Y(5) 0 0 1 -1 0 0 1
Y(6) 0 0 1 0 -1 0 1
Y(7) 0 0 0 1 -1 0 1
Y(8) 0 0 0 1 0 -1 1
Y(9) 0 0 0 0 1 -1 1
Y(10) -1 0 0 0 1 0 1
Y(11) -1 0 0 0 0 1 1
Y(12) 0 -1 0 0 0 1 1
Y(13) 1 0 0 -1 0 0 1
Y(14) 0 1 0 0 -1 0 1
Y(15) 0 0 1 0 0 -1 1
R* 1 1 1 1 1 1 0
R* = AVERAGE VALUE OF 6 REFERENCE CELLS
P = LEFT-RIGHT BIAS
FACTORS FOR COMPUTING STANDARD DEVIATIONS
V FACTOR CELLS
1 1 1 1 1 1
1 0.3727 +
1 0.3727 +
1 0.3727 +
1 0.3727 +
1 0.3727 +
1 0.3727 +
| |||
| Explanation of notation and interpretation of tables | |||